Aerosol containers hold compressed or liquefied propellants under pressure. Their internal pressure changes with temperature and formulation characteristics, while the container itself must withstand the pressure generated by its contents.
Aerosol pressure testing helps evaluate these pressure-related properties during container development, product evaluation, and manufacturing quality assurance. However, not all pressure tests measure the same thing. Measuring the internal pressure of a filled aerosol pack is different from testing an empty container’s resistance to deformation or bursting.
Understanding these differences helps aerosol brands select appropriate containers, evaluate product configurations, and identify the relevant industry standards before commercial production.
What Is Aerosol Pressure Testing?
Aerosol pressure testing refers to the measurement or evaluation of pressure-related properties in aerosol containers and filled aerosol packages.
Different methods answer different questions:
- Internal pressure measurement: Determines the pressure inside a filled aerosol product under specified temperature and measurement conditions.
- Pressure resistance testing: Evaluates whether a container can withstand a defined pressure without unacceptable damage.
- Deformation pressure testing: Identifies the pressure at which a container begins to deform.
- Burst pressure testing: Determines the pressure at which a container ruptures or otherwise fails.
These measurements are related, but they are not interchangeable. A filled aerosol product may have a particular internal pressure while its empty container has a separate pressure resistance specification.
The complete package also matters. Container material, geometry, wall construction, valve attachment, and formulation all influence the relevant evaluation. For an overview of the package structure, see aerosol can components.
How Much Pressure Can an Aerosol Can Have?
There is no single universal PSI value for all aerosol cans. Internal pressure depends on the propellant, formulation, filling conditions, temperature, and container design.
A product using a liquefied hydrocarbon propellant may behave differently from one using compressed gas. Even products with similar propellants can have different pressure characteristics because their formulations and filling ratios differ.
It is also important to distinguish the pressure inside a filled can from the pressure used to test the container.
Working Pressure or Internal Pressure
Internal pressure is the pressure exerted by the contents inside a filled aerosol container under specified conditions.
It changes with temperature. As temperature rises, the pressure of many aerosol systems increases, particularly when they contain liquefied propellants. The exact pressure-temperature relationship depends on the propellant system and formulation.
For meaningful comparisons, pressure readings should always be associated with the measurement temperature and product configuration.
Test Pressure
Test pressure is a defined pressure applied during a particular test to evaluate whether a container meets a specified requirement.
For example, an empty container may undergo a hydraulic pressure resistance test before it is approved for filling. The test pressure is not necessarily the pressure that the finished aerosol product normally experiences during storage or use.
Deformation Pressure
Deformation pressure is the pressure at which a container begins to show visible or measurable deformation under a specified test method.
Deformation does not necessarily mean the container has ruptured. It indicates that the container has reached a structural response that must be assessed against the applicable design or testing criteria.
Burst Pressure
Burst pressure is the pressure at which a container ruptures or fails.
It is used to evaluate structural resistance and container design. It must not be confused with normal internal pressure, filling pressure, or an acceptable operating limit.
PSI, Bar, and Other Pressure Units
Pressure testing commonly uses several units:
| Unit | Meaning |
|---|---|
| PSI | Pounds per square inch |
| Bar | Metric pressure unit |
| MPa | Megapascal |
| kPa | Kilopascal |
Useful conversions include:
- 1 bar ≈ 14.5 PSI
- 1 MPa = 10 bar
- 1 bar = 100 kPa
When comparing pressure specifications, check whether the value is gauge pressure or absolute pressure. Gauge pressure is measured relative to atmospheric pressure and is commonly used in aerosol container specifications.
A pressure value is meaningful only when its context is clear: the container type, temperature, test method, and whether it represents internal pressure, test pressure, or burst pressure.
What Factors Affect Aerosol Can Pressure?
Several factors influence the internal pressure of a filled aerosol product and the pressure resistance required of its container.
Propellant Type
Propellants have different pressure characteristics. Liquefied propellants maintain an equilibrium between their liquid and vapor phases inside the container, while compressed gases behave differently as the gas volume and temperature change.
Hydrocarbon propellants and dimethyl ether are commonly used in aerosol formulations, but their pressure behavior is not identical to that of compressed gases.
Propellant selection therefore affects formulation development and pressure evaluation. Learn more about aerosol propellant types.
Temperature
Temperature is a major factor in aerosol pressure behavior. As the product warms, internal pressure generally increases. This is particularly important during storage and transportation, when products may encounter different environmental conditions.
Testing requirements often specify a reference temperature because a pressure reading without its corresponding temperature can be misleading.
Aerosol containers should never be heated as an informal way to investigate pressure behavior. Pressure-related evaluations require suitable equipment and controlled test conditions.
Formulation Composition
The liquid formulation, propellant ratio, and physical properties of the product influence the internal pressure of the finished package.
Solvents, water content, active ingredients, and other components may affect how the formulation behaves with the selected propellant. Changes to the formulation can therefore require a review of the product’s pressure characteristics.
Container Material and Design
Container material and structural design determine how the package responds to internal pressure.
Relevant factors include:
- Steel, aluminum, plastic, or other container material
- Wall thickness and material properties
- Container diameter and overall geometry
- Bottom and shoulder design
- Manufacturing quality and structural consistency
- Valve attachment and closure configuration
For more information about the differences between common container materials, see the guide to aerosol can materials.
Internal product pressure and structural pressure resistance must be evaluated separately. A formulation’s pressure behavior does not, by itself, establish whether a particular container design is suitable.
Common Aerosol Pressure Testing Methods
Different aerosol testing methods are used during container development, product evaluation, and production. The appropriate method depends on whether the sample is empty or filled and what property needs to be assessed.
Internal Pressure Measurement
FEA 604 covers the measurement of internal pressure in filled aerosol packs.
The method is intended to obtain an internal gauge pressure reading while minimizing disturbance to the actual pressure in the package. Measurements are associated with a defined temperature so that results can be interpreted consistently.
Internal pressure measurement can help manufacturers and product developers evaluate whether a filled aerosol product behaves as expected under specified conditions.
It does not determine the container’s burst pressure or independently prove that the package is leakproof. For the standard’s scope, refer to FEA 604 – Filled Aerosol Packs: Measurement of Internal Pressure.
Hydraulic Pressure Resistance Test
Hydraulic testing is used to evaluate the pressure resistance of aerosol containers. FEA 621 describes a method for empty containers without valves.
At a general level, the method uses water as the pressure-transmitting medium. The container is connected to a suitable hydraulic system and evaluated under controlled conditions.
The assessment can establish whether the container withstands its specified test pressure and can also determine deformation and burst pressure.
Water-based hydraulic testing is useful because liquids are far less compressible than gases. This generally reduces the amount of stored energy compared with pressurizing a similar test volume using compressed gas. However, a container can still fail violently, so testing requires appropriate protective equipment and qualified personnel.
FEA 621 covers several distinct evaluations:
- Verification that the container meets its prescribed test pressure
- Measurement of actual deformation pressure
- Verification against a calculated burst pressure
- Measurement of actual bursting pressure
The standard applies to empty aerosol containers without valves. See FEA 621 – Measurement of Internal Pressure Resistance of Empty Containers.
Deformation Pressure Test
A deformation pressure test identifies the pressure at which a container begins to change shape under the defined test conditions.
This information helps evaluate the mechanical performance of a container design. It can also help identify differences between container constructions or material specifications.
Deformation is not the same as bursting. A container may show measurable deformation before it reaches the pressure at which it ruptures. The results should therefore be interpreted according to the applicable test method and design criteria.
Burst Pressure Test
Burst testing determines the pressure at which a container fails.
It is primarily relevant to container design evaluation and structural resistance assessment. The test may also record the location and type of failure, which can provide information about the container’s mechanical performance.
Burst testing is a destructive evaluation. It is not a routine check that should be performed on every finished aerosol product, nor does the measured burst pressure represent a suitable working pressure.
Pressure Testing of Filled Aerosol Packages
Filled aerosol packages require a different approach from empty-container hydraulic testing.
Their evaluation may involve internal pressure measurement, hot water bath testing, or an approved alternative leakproofness method, depending on the applicable requirements.
For example, US transport regulations under 49 CFR §173.306 generally require filled aerosol containers to undergo a hot water bath test designed to produce the relevant internal pressure condition. The regulation also provides alternative methods subject to specific conditions.
These filled-product evaluations consider leakage and permanent deformation, not simply the structural burst resistance of an empty can. A hot water bath test should therefore not be described as identical to an empty-container hydraulic burst test.
Aerosol Pressure Testing Standards and Regulations
Several industry standards and regulatory frameworks address different aspects of aerosol pressure evaluation.
FEA Industry Standards
The European Aerosol Federation lists several relevant methods:
- FEA 604: Measurement of internal pressure in filled aerosol packs.
- FEA 621: Measurement of internal pressure resistance of empty containers without valves.
- FEA 623: A simplified method for measuring the mechanical resistance of metal and plastic containers fitted with a valve.
FEA 623 is particularly relevant because it considers a filled aerosol package with its valve attached, rather than evaluating an empty container alone. It supports mechanical resistance assessment during product development and package evaluation.
The three standards have different scopes. They should not be treated as interchangeable certifications or as automatic substitutes for legal requirements. See the European Aerosol Federation standards list.
UN Recommendations on the Transport of Dangerous Goods
The UN Model Regulations, Part 6, address the construction and testing of dangerous goods packaging, including aerosol dispensers.
Section 6.2.4 covers aerosol dispenser requirements, including internal pressure conditions and leakproofness testing of filled packages. It also describes the hot water bath method and provisions for approved alternatives.
These provisions concern transport-related requirements and should be distinguished from industry methods for evaluating the pressure resistance of empty containers.
Refer to the UN Recommendations on the Transport of Dangerous Goods, Part 6.
US 49 CFR §173.306
In the United States, 49 CFR §173.306 establishes conditions for certain limited-quantity compressed gas shipments, including aerosol containers.
Its provisions address authorized container types, pressure conditions, and testing of filled aerosol packages. For example, the regulation specifies pressure conditions at 130°F for determining which metal aerosol container specifications are authorized. It also describes filled-container testing and certain alternative procedures.
These figures are tied to particular US transport provisions and container specifications. They are not universal operating pressure limits for every aerosol product.
See 49 CFR §173.306.
EU Aerosol Dispensers Directive 75/324/EEC
The EU Aerosol Dispensers Directive establishes requirements for aerosol dispensers placed on the European market.
Its provisions address container test pressure, filling conditions, and inspection of empty and filled aerosol dispensers. The specific requirements depend on the container material and product configuration.
For example, the directive distinguishes between metal containers filled under different pressure conditions when specifying minimum container test pressure. It also addresses filled-product inspection for leakage and permanent deformation.
Refer to EU Aerosol Dispensers Directive 75/324/EEC.
Aerosol Pressure Testing vs. Leak Testing
Pressure testing and leak testing are related, but they answer different questions.
| Evaluation | Main Purpose |
|---|---|
| Pressure testing | Evaluates pressure-related properties or container resistance |
| Leak testing | Evaluates whether product or propellant escapes through the container or closure |
| Burst testing | Determines the pressure at which a container fails |
| Stability testing | Evaluates product and package changes during storage |
A container may withstand a specified pressure without bursting but still have a leakage problem at a valve or seal. Likewise, passing a leak test does not automatically prove that the container meets a particular burst pressure requirement.
Stability testing addresses a broader question: how the product and package change over time. It may include monitoring pressure-related changes and package weight during storage, but it is not a substitute for a defined pressure resistance test.
For more information, see the guide to aerosol stability testing.
Why Aerosol Pressure Testing Matters in Manufacturing
Pressure evaluation helps manufacturers and product brands make informed decisions about container design, formulation, and packaging suitability.
It can support:
- Container design evaluation: Assessing whether a container construction meets its intended pressure resistance requirements.
- Packaging selection: Comparing material and structural options for a specific aerosol product.
- Product development: Understanding how propellant and formulation choices affect internal pressure.
- Quality assurance: Identifying pressure-related weaknesses during appropriate development or production checks.
- Regulatory preparation: Supporting evaluations required by the applicable market and transport framework.
However, pressure testing alone does not guarantee complete product safety. Package integrity, leakproofness, formulation compatibility, filling controls, and other relevant evaluations also need consideration.
TENTOP CHEM, the brand of Zhongshan Tentop Fine Chemical Co., Ltd., provides aerosol OEM/ODM manufacturing services, including formulation development and adjustment, aerosol filling, BOV production, liquid filling, and packaging coordination. Its facilities include four high-speed aerosol filling lines, three BOV production lines, and two liquid filling lines.
As a manufacturing partner, TENTOP CHEM considers formulation, propellant, filling, and packaging requirements during product development and production planning. Specialized pressure resistance assessments should be arranged with appropriately qualified testing providers when required. Learn more about private label aerosol manufacturing.
Conclusion
Aerosol pressure testing covers several distinct evaluations, including internal pressure measurement, container pressure resistance, deformation pressure, and burst pressure. Each method serves a different purpose.
The correct evaluation depends on whether the sample is an empty container or a filled aerosol package, the property being investigated, and the applicable industry standard or regulatory requirement.
For brands developing a new aerosol product, understanding these distinctions helps avoid incorrect pressure specifications and supports more informed container and formulation decisions. If you are planning an aerosol product or reviewing its packaging requirements, contact TENTOP CHEM to discuss formulation development, filling, packaging coordination, and OEM/ODM manufacturing.